Hydronic operation

    There are rooms where cleanliness and hygiene are high priorities, such as hospitals and doctors' surgeries, for example. Zehnder Charleston Clinic is there to help. Ample clearance between the individual elements of the radiator ensures cleaning is a simple process. The Zehnder EasyFix fixing system for simple and anti-lift assembly ensures easy installation. Available in almost any colour and finish from the Zehnder colour chart.

    Benefits

    • Wide range of models supports versatile use
    • The Zehnder EasyFix fixing system ensures simple and anti-lift assembly
    • Classic, elegant design blends in with any setting
    • Ample spaces between tubes make cleaning easy
    • High proportion of radiation ensures comfort
    • Retrofit models available for existing pipework, providing simple installation for renovation projects
    • Compatible with a heat pump and/or low-temperature systems
    • Special solutions support a wide range of application, such as curved or angled
    • Easy to clean and perfect for people suffering from allergies thanks to its smooth surface
    • Adaptable to the construction situation thanks to element construction
    • High level of heat capacity also for old buildings with a high heating load
    • Residue-free laser welding technology “LaZer made” guarantees maximum quality, high-end design and reliable operation of the heating system

    Colour System

    Zehnder Charleston Clinic - Hydronic operation
    Traffic White (9016* / RAL 9016)
    * These colours / surfaces are glossy, all others matt.
    Despite extreme care in the painting process of our radiators, slight colour deviations are possible, depending on the production series and compared to other colour carriers (ceramic, paper, metal, ...) as well as screen display.
    RAL and NCS are manufacturer's designations.

    Technical data

    Connection to hot water central heating system

    Model 2-column
    Model H L T Heat output
    75/65/20 °C 70/55/20 °C 55/45/20 °C
    mm mm mm Watts Watts Watts
    K2019 177 65 62 17.2 13.9 8.9
    K2026 260 65 62 23.9 19.3 12.3
    K2030 300 65 62 26.5 21.4 13.7
    K2035 350 65 62 30.4 24.6 15.7
    K2040 400 65 62 34.2 27.7 17.6
    K2045 450 65 62 37.9 30.7 19.6
    K2050 500 65 62 41.6 33.7 21.5
    K2055 550 65 62 45.2 36.6 23.3
    K2060 600 65 62 48.8 39.5 25.2
    K2075 750 65 62 59.2 48 30.6
    K2090 900 65 62 69.4 56.1 35.7
    K2100 1000 65 62 76 61.5 39.1
    K2110 1100 65 62 82.6 66.8 42.5
    K2120 1200 65 62 91.1 73.7 46.8
    K2150 1500 65 62 115 92.6 58.3
    K2180 1800 65 62 139 112 69.7
    K2200 2000 65 62 156 126 78.6
    K2220 2200 65 62 172 138 86.7
    K2250 2500 65 62 195 157 98.8
    K2280 2800 65 62 219 177 112
    K2300 3000 65 62 235 190 120
    H = height, L = length, T = depth
    75/65/20 = Nominal heat output according to EN 442
    Model 3-column
    Model H L T Heat output
    75/65/20 °C 70/55/20 °C 55/45/20 °C
    mm mm mm Watts Watts Watts
    K3019 185 65 100 23.2 18.9 12.1
    K3026 260 65 100 31.2 25.3 16.3
    K3030 300 65 100 35.4 28.8 18.5
    K3035 350 65 100 40.6 32.9 21.1
    K3040 400 65 100 45.7 37.1 23.7
    K3045 450 65 100 50.8 41.2 26.4
    K3050 500 65 100 55.9 45.4 29
    K3055 550 65 100 61 49.4 31.5
    K3060 600 65 100 66 53.5 34.1
    K3075 750 65 100 81.1 65.6 41.7
    K3090 900 65 100 96.3 77.8 49.3
    K3100 1000 65 100 107 86.3 54.5
    K3110 1100 65 100 117 94.4 59.6
    K3120 1200 65 100 127 102 64.3
    K3150 1500 65 100 158 127 80
    K3180 1800 65 100 189 152 95.3
    K3200 2000 65 100 209 168 106
    K3220 2200 65 100 229 185 116
    K3250 2500 65 100 260 210 132
    K3280 2800 65 100 290 234 147
    K3300 3000 65 100 311 251 158
    H = height, L = length, T = depth
    75/65/20 = Nominal heat output according to EN 442
    Model 4-column
    Model H L T Heat output
    75/65/20 °C 70/55/20 °C 55/45/20 °C
    mm mm mm Watts Watts Watts
    K4019 200 65 136 32.1 26.1 16.8
    K4026 260 65 136 40.4 32.9 21.2
    K4030 300 65 136 45.8 37.3 24
    K4035 350 65 136 52.5 42.7 27.5
    K4040 400 65 136 59.2 48.1 30.9
    K4045 450 65 136 65.7 53.4 34.3
    K4050 500 65 136 72.3 58.8 37.7
    K4055 550 65 136 78.8 64 40.9
    K4060 600 65 136 85.4 69.3 44.4
    K4075 750 65 136 105 85.1 54.3
    K4090 900 65 136 125 101 64.3
    K4100 1000 65 136 138 112 70.6
    K4110 1100 65 136 151 122 76.9
    K4120 1200 65 136 165 133 84
    K4150 1500 65 136 204 165 105
    K4180 1800 65 136 244 197 125
    K4200 2000 65 136 270 218 138
    K4220 2200 65 136 296 239 151
    K4250 2500 65 136 335 270 171
    K4280 2800 65 136 375 303 191
    K4300 3000 65 136 401 324 204
    H = height, L = length, T = depth
    75/65/20 = Nominal heat output according to EN 442
    Model 5-column
    Model H L T Heat output
    75/65/20 °C 70/55/20 °C 55/45/20 °C
    mm mm mm Watts Watts Watts
    K5019 200 65 173 39.2 31.9 20.5
    K5026 260 65 173 49.4 40.3 26
    K5030 300 65 173 56 45.7 29.5
    K5035 350 65 173 64.2 52.4 33.9
    K5040 400 65 173 72.3 58.9 37.9
    K5045 450 65 173 80.4 65.5 42.2
    K5050 500 65 173 88.4 72 46.4
    K5055 550 65 173 96.4 78.4 50.3
    K5060 600 65 173 104 84.6 54.3
    K5075 750 65 173 128 104 66.5
    K5090 900 65 173 152 123 78.6
    K5100 1000 65 173 168 136 86.4
    K5110 1100 65 173 185 150 94.7
    K5120 1200 65 173 201 163 103
    K5150 1500 65 173 249 202 128
    K5180 1800 65 173 297 241 154
    K5200 2000 65 173 330 267 169
    K5220 2200 65 173 362 293 185
    K5250 2500 65 173 410 331 210
    K5280 2800 65 173 458 370 235
    K5300 3000 65 173 490 396 251
    H = height, L = length, T = depth
    75/65/20 = Nominal heat output according to EN 442
    Model 6-column
    Model H L T Heat output
    75/65/20 °C 70/55/20 °C 55/45/20 °C
    mm mm mm Watts Watts Watts
    K6019 200 65 210 46.1 37.5 24.1
    K6026 260 65 210 58.1 47.1 30.2
    K6030 300 65 210 65.9 53.4 34.1
    K6035 350 65 210 75.5 61.2 39
    K6040 400 65 210 85.1 69 44
    K6045 450 65 210 94.6 76.7 48.9
    K6050 500 65 210 104 84.3 53.8
    K6055 550 65 210 113 91.6 58.4
    K6060 600 65 210 123 99.7 63.6
    K6075 750 65 210 151 122 77.7
    K6090 900 65 210 179 145 92.1
    K6100 1000 65 210 198 160 102
    K6110 1100 65 210 217 176 112
    K6120 1200 65 210 236 191 122
    K6150 1500 65 210 293 237 150
    K6180 1800 65 210 349 282 178
    K6200 2000 65 210 387 313 198
    K6220 2200 65 210 425 344 218
    K6250 2500 65 210 481 389 248
    K6280 2800 65 210 537 435 276
    K6300 3000 65 210 575 466 296
    H = height, L = length, T = depth
    75/65/20 = Nominal heat output according to EN 442